MCB & Distribution Boards - Exporter & Manufacturer, New Delhi, India
CAPITAL
MCB & Distribution Boards
To inquire, Select Product/s & Click on

Product Code : 05

[Select]
Product Specification
MCB

Protection:
  • Thermal Overload
  • Magnetic Short Circuit
  • Finger & Hand Tourch
  • High Strength, Unbreakable, Flame Retardant Housing Material
  • over load
  • Against moist conditions
  • Finger & hand touch safe
Advantage:
  • Quick make Quick break with trip free mechanism
  • ISI marked
  • No line load restrictions
  • Silver Inlay contacts
  • No backup fuse is required
  • Cannot be switched on until the fault is cleared
  • Available in "B" and "C" characteristics
  • Calibrated at 40oC
Features:
  • Housed in Hi-Tech glass fibre filled polyester
  • Ensures high electrical-Mechanical properties
  • Din rail mounting
  • Confirms to the latest international standards
  • Incoming terminal suitable for both cable connections and bus bar
  • Potential free
    • DIN Clip
    • Compact size.
Technical Data C-MCB:
Current Rating
0.5 to 63A
Voltage Rating
240/415 VAC
Breaking Capacity
len ultimate breaking capacity 10000A
Degree of Protection
1 P 20
Rated Frequency
50 Hz / 60 Hz
Tripping Characteristics
"B" curve: The magnetic trip unit operate between 3-5 in
"C" curve: The magnetic trip units operate between 5-10 In.
Connections
Terminal Capacity
1-25mm output, 1-35mm input

Tighning Touque
2 Nm
Ambient Temp.
T Max. = 55oC, T mm = 5oC.
Number of Poles
SP, SPN, D.P., T.P., TPN, F.P.
Insulation Voltage
500V
Specification
IS -8828-1996 IEC 898-1995

MCB For Protection Against Over-Current:
Every sb-circuit is required to be protected from effects of over current which may be due to overload or short circuit. The thermal and magnetic elements of a MCB detect both theover current and short circuit and the circuit breaker operates and interrupts the supply to minimise the damage.

MCB For Protection Against Indirect Contact:
An electric shock may be experienced as a result of direct of indirect contact. A MCB when used in conjunction with earthed equipotential bonding can be used as a basic protective measure for protection against indirect. It is important that the maximum earth fault loop impedance (z) of the circuit being protected does not exceed the values given below (Typical).

The electrical wiring is carried out to distribute current from a single source of suply to various circuits, such arrangement of circuits is made inside an enclosure called Distribution Board.

The Distribution Board is not merely an enclosure but a comprehensive system in  itself, comprising of copper bus bars, brass neutral links, earth links to facilitate effective distribution of current.  It incorporates safety devices such as MCBs, ELCBs  and islators, which serves to protect the installation.

A wide range of compact, elegant & economical DBs with unique featurs, designed & engineered to provide user safety, convenience and operational / maintenance advantages are offered.

Range
Single Phase & Three Phase Distribution Boards.

Specification
IS 13032

Features:
  • Aesthetically superiors DBs to suit the style of your home decor
  • Choice of multiple incomer MCB, Isolators, MCB + RCCB, Changeover + RCCB, Isolator + RCCB
  • When Per phase isolation DBs is in use, only that phase where the Earth leakage faults exist get
  • Complete range of Dbs with detachable gland plates at the top and bottom with knockouts on the sides of DB to increase the flexibility of cables / conduit entry from all directions.
  • Ready to use DBs that are supplied with Neutral Links, Earth Links, Bus bar and inter connecting wire/links
  • Supplied with neutral link, earth links and bus bars
  • Increased cable flexibility with detachable gland plates
  • Provision for both surface and flush mounting
  • Transparent outer cover made of engineering plastics

<< Back
 
 
  Contact Details
CAPITAL
Rajdhani Enterprises, 29, Netaji Subhash Marg, Darya Ganj,New Delhi - 110002, India
Phone:91-11-23245533
Fax:91-11-23245834